Electronic Combination Locks

AuditGard
The AuditGard Series offers multiple user functions as well as audit functions. Customised versions have to be created by adding functions via the LA GARD
PC programming software.

The eKey function permits the opening of the lock by the code and the eKey.

Different input units - all in metal design - are available with a soft keypad or a foil keypad. The spy proof version “3190” can also be used with the AuditGard series.

According to the safe application, a deadbolt or a swingbolt locking system can be chosen. The patented swingbolt technology offers a spindle-less system which moves the bolt by the operation of the bolt work.

In case of the optional override solution an electronic deadbolt lock and a mechanical combination lock come into operation. For the lock opening an input unit and a dial & ring combination are necessary. However for the override opening only the dial & ring combi-nation has to be operated.
Technical Information & Drawings

Input unit 3125














Approvals/Certificates
3125
Input unit
3190
Input unit
3750-K
Input unit
8130
Input unit
Lock LA GARD 4300M
EN 1300 B B B B
VdS Class 2 Class 2 Class 2 Class 2
ECB-S B B B -
UL Type 1 Type 1 Type 1 -
DNV 158:2 158:2 158:2 -
Lock LA GARD 6040M-DB
EN 1300 B B B B
VdS Class 2 Class 2 Class 2 Class 2
ECB-S B B B -
UL Type 1 Type 1 Type 1 -
DNV 158:2 158:2 158:2 -
Lock LA GARD 6441-1
EN 1300 B C B B
VdS Class 2 Class 3 Class 2 Class 2
ECB-S B C B -
UL Type 1 Type 1 Type 1 -
DNV - - - -


Codes
1 Control code*
1 Manager*
8 Users*


Lock functions
Time Delay
Dual Mode*
Time Delay Override*
Add/Delete User code (Manager only)
Enable/Disable User code (Manager only)
Add/Delete Manager code (Control code only)*
Enable/Disable Manager code (Control code only)*
Remote disable lock opening*/**
Remote disable lock*/**
Silent Alarm*/**
Audit (record of last 512 events)
Lock opening only by code
Lock opening by code and eKeyII (material identification), activation with reset box

* Activation by PC software required
** Battery box with alarm function or separate Alarm Interface (VdS listed) required


General functions
Low battery signal
Wrong try lockout after 4 false codes


Power supply
1 x 9 volt block battery (not included in delivery) or
6 x 1.5 volt C-cell battery, recommended for time delay (not included in delivery)


Lock
Die-cast lock case and bolt, bolt with 2 M4 threads (only for deadbolt)
Lock mounting set, incl. 3 screws M6
Admissible mounting positions

Deadbolt:
Right hand/left hand lock (upside down mounting), opening clockwise
Swingbolt:
Right hand/left hand lock (upside down mounting, dual-handed)